Manual:CRS1xx/2xx series switches examples: Difference between revisions

From MikroTik Wiki
Jump to navigation Jump to search
added mirroring examples
No edit summary
 
(186 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Versions| v6.6 +}}
{{Versions| v6.41 +}}
 
{{Warning|This manual is moved to [[https://help.mikrotik.com/docs/pages/viewpage.action?pageId=103841836 CRS1xx/2xx series switches examples]]}}


__TOC__
__TOC__




===Summary===
=Summary=
 
Basic use cases and configuration examples for Cloud Router Switch features.
 
{{Warning | This article applies to CRS1xx and CRS2xx series switches and not to CRS3xx series switches. For CRS3xx series devices read the [[Manual:CRS3xx_series_switches | CRS3xx series switches]] manual.}}


Basic switch-chip configuration examples for Cloud Router Switch.
=Port switching=


{{Note | More examples are about to be added.}}
In order to setup port switching on CRS1xx/2xx series switches, check the [[Manual:Interface/Bridge#Bridge_Hardware_Offloading | Bridge Hardware Offloading]] page.


{{ Warning | It is possible to create multiple isolated switch group by using multiple bridges with enabled hardware offloading, this is possible only on CRS1xx/2xx series switches. For more complex setups (for example, VLAN filtering) you should use the port isolation feature instead. }}


===VLAN===
{{ Note | Port switching in RouterOS v6.41 and newer is done using the bridge configuration. Prior to RouterOS v6.41 port switching was done using the <var>master-port</var> property, for more details check the [[Manual:Master-port | Master-port]] page. }}


====Port Based VLAN====
=Management access configuration=


[[File:Port-Based.png|center|frame|alt=Alt text|Port Based VLAN]]
In general, switches are only supposed to forward packets by using the built-in switch chip, but not allow access to the device itself for security reasons. It is possible to use device's serial port for management access, but in most cases such an access method is not desired and access using an IP address is more suitable. In such cases you will need to configure management access.


* Create a group of switched ports and configure switch for IEEE 802.1Q bridging.
In all types of management access it is assumed that ports must be switched together, use the following commands to switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether5 hw=yes
</pre>


You should also assign an IP address to the bridge interface so the device is reachable using an IP address (the device is also reachable using a MAC address):
<pre>
/ip address
add address=192.168.88.1/24 interface=bridge1
</pre>
==Untagged==
If invalid VLAN filtering is not enabled, management access to the device using tagged or untagged ('''VLAN 0''') traffic is already allowed from any port, though this is not a good practice, this can cause security issues and can cause the device's CPU to be overloaded in certain situations (most commonly with broadcast type of traffic).
If you are intending to use invalid VLAN filtering (which you should), then ports, from which you are going to access the switch, must to be added to the VLAN table for untagged ('''VLAN 0''') traffic, for example, in case you want to access the switch from '''ether2''':
<pre>
/interface ethernet switch vlan
add vlan-id=0 ports=ether2,switch1-cpu
</pre>
==Tagged==
Allowing only tagged traffic to have management access to the device through a specific port is a much better practice. For example, to allow only '''VLAN99''' to access the device through '''ether2''' you should first add an entry to the VLAN table, which will allow the selected port and the CPU port ('''switch1-cpu''') to forward the selected VLAN ID, therefore allowing management access:
<pre>
/interface ethernet switch vlan
add ports=ether2,switch1-cpu vlan-id=99
</pre>
Packets that will be sent out from the CPU, for example, ping replies will not have a VLAN tag, to solve this you need to specify which ports should always send out packets with a VLAN tag for a specific VLAN ID:
<pre>
/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2,switch1-cpu vlan-id=99
</pre>
After valid VLAN99 configuration has been setup, you can enable unknown/invalid VLAN filtering, which will not allow the management access through different ports than specified in the VLAN table:
<pre>
<pre>
/interface ethernet
set ether6 master-port=ether2
set ether7 master-port=ether2
set ether8 master-port=ether2
/interface ethernet switch
/interface ethernet switch
set bridge-type=customer-vlan-bridge
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether3,ether4,ether5
</pre>
 
In this example VLAN99 will be used to access the device, a VLAN interface on the bridge must be created and an IP address must be assigned to it.
<pre>
/interface vlan
add interface=bridge1 name=MGMT vlan-id=99
/ip address
add address=192.168.99.1/24 interface=MGMT
</pre>
</pre>


* Tag ingress traffic coming from each of the access ports by assigning new VLAN ids for untagged (VLAN id 0) frames.
=VLAN=
 
{{Note | It is recommended to get Serial Console cable and test it before configuring VLANs because you
may lose access to the CPU and/or the port you are connected to.}}
 
{{Note | Some changes may take some time to take effect due to already learned MAC addreses. In such cases flushing Unicast Forwarding Database can help: <code>/interface ethernet switch unicast-fdb flush</code>}}
 
{{Warning | Multiple hardware offloaded bridge configuration is designed as fast and simple port isolation solution, but it limits part of VLAN functionality supported by CRS switch-chip.
For advanced configurations use one bridge within CRS switch chip for all ports, configure VLANs and isolate port groups with port isolation profile configuration.}}
 
==Port Based VLAN==
 
{{ Note | For CRS3xx series devices you must use bridge VLAN filtering, you can read more about it in the [[ Manual:Interface/Bridge#Bridge_VLAN_Filtering | Bridge VLAN Filtering]] section. }}
 
===Example 1 (Trunk and Access ports)===
 
[[File:Port-Based.png|center|frame|alt=Alt text|Port Based VLAN 1]]


Switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
Specify the VLAN ID that the switch must set on untagged (VLAN0) traffic for each access port:
<pre>
<pre>
/interface ethernet switch ingress-vlan-translation
/interface ethernet switch ingress-vlan-translation
add port=ether6 customer-vid=0 new-customer-vid=200 sa-learning=yes
add ports=ether6 customer-vid=0 new-customer-vid=200
add port=ether7 customer-vid=0 new-customer-vid=300 sa-learning=yes
add ports=ether7 customer-vid=0 new-customer-vid=300
add port=ether8 customer-vid=0 new-customer-vid=400 sa-learning=yes
add ports=ether8 customer-vid=0 new-customer-vid=400
</pre>
 
{{ Note | When an entry is created under <code>/interface ethernet switch ingress-vlan-translation</code>, then the switch chip will add a VLAN tag on ingress frames on the specified port. To remove the VLAN tag on the same port for egress frames, an <code>/interface ethernet switch egress-vlan-tag</code> entry should be created for the same VLAN ID where only tagged ports are specified. If specific VLAN is forwarded only between access ports, the <code>/interface ethernet switch egress-vlan-tag</code> entry should still be created without any tagged ports. Another option is to create extra entries under <code>/interface ethernet switch egress-vlan-translation</code> menu to set untagged (VLAN0) traffic.}}
 
You must also specify which VLANs should be sent out the trunk port with a VLAN tag. Use the <var>tagged-ports</var> property to setup a trunk port:
<pre>
/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=200
add tagged-ports=ether2 vlan-id=300
add tagged-ports=ether2 vlan-id=400
</pre>
</pre>


* Untag egress traffic on access ports by replacing current VLAN ids with VLAN id 0.
Add entries to the VLAN table to specify VLAN memberships for each port and each VLAN ID:
<pre>
/interface ethernet switch vlan
add ports=ether2,ether6 vlan-id=200
add ports=ether2,ether7 vlan-id=300
add ports=ether2,ether8 vlan-id=400
</pre>


After valid VLAN configuration has been setup, you can enable unknown/invalid VLAN filtering:
<pre>
<pre>
/interface ethernet switch egress-vlan-translation
/interface ethernet switch
add port=ether6 customer-vid=200 new-customer-vid=0
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8
add port=ether7 customer-vid=300 new-customer-vid=0
add port=ether8 customer-vid=400 new-customer-vid=0
</pre>
</pre>


====Protocol Based VLAN====
{{ Note | It is possible to use the built-in switch chip and the CPU at the same time to create a Switch-Router setup, where a device acts as a switch and as a router at the same time. You can find a configuration example in the [[Manual:CRS_Router | CRS-Router]] guide. }}


[[File:Protocol-Based.png|center|frame|alt=Alt text|Protocol Based VLAN]]
===Example 2 (Trunk and Hybrid ports)===
 
[[File:Port-Based-e2.png|center|frame|alt=Alt text|Port Based VLAN 2]]
 
Switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>


* Create a group of switched ports.
Specify the VLAN ID that the switch must set on untagged (VLAN0) traffic for each access port:
<pre>
/interface ethernet switch ingress-vlan-translation
add ports=ether6 customer-vid=0 new-customer-vid=200
add ports=ether7 customer-vid=0 new-customer-vid=300
add ports=ether8 customer-vid=0 new-customer-vid=400
</pre>


By specifying ports as <var>tagged-ports</var>, the switch will always send out packets as tagged packets with the corresponding VLAN ID. Add appropriate entries according to the diagram above:
<pre>
<pre>
/interface ethernet
/interface ethernet switch egress-vlan-tag
set ether6 master-port=ether2
add tagged-ports=ether2,ether7,ether8 vlan-id=200
set ether7 master-port=ether2
add tagged-ports=ether2,ether6,ether8 vlan-id=300
set ether8 master-port=ether2
add tagged-ports=ether2,ether6,ether7 vlan-id=400
</pre>
</pre>


* Set VLAN for IP and ARP protocols
Add entries to the VLAN table to specify VLAN memberships for each port and each VLAN ID:
<pre>
/interface ethernet switch vlan
add ports=ether2,ether6,ether7,ether8 vlan-id=200 learn=yes
add ports=ether2,ether6,ether7,ether8 vlan-id=300 learn=yes
add ports=ether2,ether6,ether7,ether8 vlan-id=400 learn=yes
</pre>


After valid VLAN configuration has been setup, you can enable unknown/invalid VLAN filtering:
<pre>
/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8
</pre>
==Protocol Based VLAN==
[[File:Protocol-Based.png|center|frame|alt=Alt text|Protocol Based VLAN]]
Switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
Set VLAN for IP and ARP protocols:
<pre>
<pre>
/interface ethernet switch protocol-based-vlan
/interface ethernet switch protocol-based-vlan
Line 69: Line 211:
</pre>
</pre>


* Set VLAN for IPX protocol
Set VLAN for IPX protocol:
 
<pre>
<pre>
/interface ethernet switch protocol-based-vlan
/interface ethernet switch protocol-based-vlan
Line 77: Line 218:
</pre>
</pre>


Set VLAN for AppleTalk AARP and AppleTalk DDP protocols
Set VLAN for AppleTalk AARP and AppleTalk DDP protocols:
 
<pre>
<pre>
/interface ethernet switch protocol-based-vlan
/interface ethernet switch protocol-based-vlan
Line 87: Line 227:
</pre>
</pre>


====MAC Based VLAN====
==MAC Based VLAN==
 
{{ Warning | Internally all MAC addresses in MAC based VLANs are hashed, certain MAC addresses can have the same hash, which will prevent a MAC address being loaded in to the switch chip if the hash matches with a hash from a MAC address that has been already loaded, for this reason it is recommended to use Port bases VLANs in combination with MAC based VLANs. This is a hardware limitation. }}


[[File:MAC-Based.png|center|frame|alt=Alt text|MAC Based VLAN]]
[[File:MAC-Based.png|center|frame|alt=Alt text|MAC Based VLAN]]


* Create a group of switched ports.
Switch together the required ports:
 
<pre>
<pre>
/interface ethernet
/interface bridge
set ether7 master-port=ether2
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
</pre>
</pre>


* Enable MAC based VLAN translation on access port.
Enable MAC based VLAN translation on access port:
 
<pre>
<pre>
/interface ethernet switch port
/interface ethernet switch port
set ether7 mac-based-vlan-translate=yes mac-based-customer-vlan=all-frames
set ether7 allow-fdb-based-vlan-translate=yes
</pre>
</pre>


* Add MAC-to-VLAN mapping entries in MAC based VLAN table.
Add MAC-to-VLAN mapping entries in MAC based VLAN table:
 
<pre>
<pre>
/interface ethernet switch mac-based-vlan
/interface ethernet switch mac-based-vlan
Line 114: Line 256:
</pre>
</pre>


* Set VLAN id untagging for tagged frames coming from the trunk port.
Add VLAN200, VLAN300 and VLAN400 tagging on ether2 port to create it as VLAN trunk port:
<pre>
/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=200
add tagged-ports=ether2 vlan-id=300
add tagged-ports=ether2 vlan-id=400
</pre>
 
Additionally, add entries to the VLAN table, specify VLAN membership for each port and enable unknown/invalid VLAN filtering, see an example below - [[ Manual:CRS1xx/2xx_series_switches_examples#Unknown.2FInvalid_VLAN_filtering | Unknown/Invalid VLAN filtering]]. This is required for network setups where more interfaces are added to the bridge, as it allows to define VLAN boundaries.
 
==InterVLAN Routing==
 
[[File:InterVLAN-Routing.png|center|frame|alt=Alt text|InterVLAN Routing]]
 
InterVLAN routing configuration consists of two main parts – VLAN tagging in switch-chip and routing in RouterOS. This configuration can be used in many applications by combining it with DHCP server, Hotspot, PPP and other features for each VLAN.
 
Switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
 
Set VLAN tagging on CPU port for all VLANs to make packets tagged before they are routed:
<pre>
/interface ethernet switch egress-vlan-tag
add tagged-ports=switch1-cpu vlan-id=200
add tagged-ports=switch1-cpu vlan-id=300
add tagged-ports=switch1-cpu vlan-id=400
</pre>


add ingress VLAN translation rules to ensure that the correct VLAN ID assignment is done on access ports:
<pre>
<pre>
/interface ethernet switch ingress-vlan-translation
/interface ethernet switch ingress-vlan-translation
add port=ether2 customer-vlan-lookup-for=tagged new-customer-vid=0 sa-learning=yes
add ports=ether6 customer-vid=0 new-customer-vid=200
add ports=ether7 customer-vid=0 new-customer-vid=300
add ports=ether8 customer-vid=0 new-customer-vid=400
</pre>
</pre>


====Management IP Configuration====
Create the VLAN interfaces on top of the bridge interface:
<pre>
/interface vlan
add name=VLAN200 interface=bridge1 vlan-id=200
add name=VLAN300 interface=bridge1 vlan-id=300
add name=VLAN400 interface=bridge1 vlan-id=400
</pre>


* Add VLAN 99 interface and assign IP address to it. Since the master-port receives all the traffic coming from switch-cpu port, VLAN has to be configured on master-port, in this case "ether2" port.  
{{ Warning | Make sure the VLAN interfaces are created on top of the bridge interface instead of any of the physical interfaces. If the VLAN interfaces are created on a slave interface, then packet might not be received correctly and therefore routing might fail. More detailed information can be found in the [[ Manual:Layer2_misconfiguration#VLAN_interface_on_a_slave_interface | VLAN interface on a slave interface]] manual page. }}


Add IP addresses to created the VLAN interfaces. In this example, three 192.168.x.1 addresses are added to VLAN200, VLAN300 and VLAN400 interfaces:
<pre>
<pre>
/interface vlan
add name=vlan99 vlan-id=99 interface=ether2
/ip address
/ip address
add address=192.168.88.1/24 interface=vlan99 network=192.168.88.0
add address=192.168.20.1/24 interface=VLAN200
add address=192.168.30.1/24 interface=VLAN300
add address=192.168.40.1/24 interface=VLAN400
</pre>
</pre>


====InterVLAN Routing with unknown VLAN filtering====
==Unknown/Invalid VLAN filtering==


[[File:InterVLAN-Routing.png|center|frame|alt=Alt text|InterVLAN Routing]]
VLAN membership is defined in the VLAN table. Adding entries with VLAN ID and ports makes that VLAN traffic valid on those ports. After valid VLAN configuration has been setup, unknown/invalid VLAN filtering can be enabled. This VLAN filtering configuration example applies to [[#InterVLAN_Routing | InterVLAN Routing]] setup.
<pre>
/interface ethernet switch vlan
add ports=switch1-cpu,ether6 vlan-id=200
add ports=switch1-cpu,ether7 vlan-id=300
add ports=switch1-cpu,ether8 vlan-id=400
</pre>
 
* Option 1: disable invalid VLAN forwarding on specific ports (more common):
<pre>
/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8
</pre>
 
* Option 2: disable invalid VLAN forwarding on all ports:
<pre>
/interface ethernet switch
set forward-unknown-vlan=no
</pre>
 
{{ Warning | Using multiple bridges on a single switch chip with enabled unknown/invalid VLAN filtering can cause unexpected behavior. You should always use a single bridge configuration whenever using VLAN filtering. If port isolation is required, then port isolation feature should be used instead of using multiple bridges. }}
 
==VLAN Tunneling (Q-in-Q)==
 
This example covers typical VLAN tunneling use case where service provider devices add another VLAN tag for independent forwarding in the mean time allowing customers to use their own VLANs.
 
{{Note | This example contains only Service VLAN tagging part. <br />
It is recommended to additionally set [[#Unknown.2FInvalid_VLAN_filtering | Unknown/Invalid VLAN filtering]] configuration on ports.}}
 
[[File:qinq.png|center|frame|alt=Alt text|Q-in-Q VLAN]]
 
 
'''CRS-1''': The first switch on the edge of service provider network has to properly indentify traffic from customer VLAN id on port and assign new service VLAN id with ingress VLAN translation rules. <br />
<br />
VLAN trunk port configuration for service provider VLAN tags is in the same ''egress-vlan-tag'' table. <br />
<br />
The main difference from basic [[#Port_Based_VLAN | Port Based VLAN]] configuration is that CRS switch-chip has to be set to do forwarding according to service (''outer'') VLAN id instead of customer (''inner'') VLAN id.
 
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether9 hw=yes
 
/interface ethernet switch ingress-vlan-translation
add customer-vid=200 new-service-vid=400 ports=ether1
add customer-vid=300 new-service-vid=500 ports=ether2
 
/interface ethernet switch egress-vlan-tag
add tagged-ports=ether9 vlan-id=400
add tagged-ports=ether9 vlan-id=500


InterVLAN routing configuration consists of two main parts – VLAN tagging in switch-chip and routing in RouterOS. This configuration can be used in many applications by combining it with DHCP server, Hotspot, PPP and other features for each VLAN. Additionally this example covers blocking of unwanted other VLAN traffic on ports.
/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid
</pre>


* Create a group of switched ports.
'''CRS-2''': The second switch in the service provider network require only switched ports to do forwarding according to service (''outer'') VLAN id instead of customer (''inner'') VLAN id.


<pre>
<pre>
/interface ethernet
/interface bridge
set ether6 master-port=ether2
add name=bridge1
set ether7 master-port=ether2
/interface bridge port
set ether8 master-port=ether2
add bridge=bridge1 interface=ether9 hw=yes
add bridge=bridge1 interface=ether10 hw=yes
 
/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid
</pre>
</pre>


* Set VLAN tagging on CPU port for all VLANs to make packets tagged before they are routed and add ingress VLAN translation rules to ensure correct VLAN id assignment is done on access ports.
'''CRS-3''': The third switch has similar configuration to CRS-1:
* Ports in a switch group using a bridge;
* Ingress VLAN translation rules to define new service VLAN assingments on ports;
* <var>tagged-ports</var> for service provider VLAN trunks;
* CRS switch-chip set to use service VLAN id in switching lookup.


<pre>
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether10 hw=yes
/interface ethernet switch ingress-vlan-translation
add customer-vid=200 new-service-vid=400 ports=ether3
add customer-vid=300 new-service-vid=500 ports=ether4
/interface ethernet switch egress-vlan-tag
/interface ethernet switch egress-vlan-tag
add tagged-ports=switch1-cpu vlan-id=200
add tagged-ports=ether10 vlan-id=400
add tagged-ports=switch1-cpu vlan-id=300
add tagged-ports=ether10 vlan-id=500
add tagged-ports=switch1-cpu vlan-id=400


/interface ethernet switch ingress-vlan-translation
/interface ethernet switch
add ports=ether6 new-customer-vid=200 sa-learning=yes
set bridge-type=service-vid-used-as-lookup-vid
add ports=ether7 new-customer-vid=300 sa-learning=yes
add ports=ether8 new-customer-vid=400 sa-learning=yes
</pre>
</pre>


* For routing add VLAN interfaces on master-port because it connects with CPU port and add IP addresses to created VLAN interfaces. In this example three 192.168.x.1 addresses are added to vlan200, vlan300 and vlan400 interfaces.
===CVID Stacking===
 
It is possible to use CRS1xx/CRS2xx series switches for CVID Stacking setups. CRS1xx/CRS2xx series switches are capable of VLAN filtering based on the outer tag of tagged packets that have two CVID tags (double CVID tag), these switches are also capable of adding another CVID tag on top of an existing CVID tag (CVID Stacking). For example, in a setup where '''ether1''' is receiving tagged packets with CVID 10, but it is required that '''ether2''' sends out these packets with another tag CVID 20 (VLAN10 inside VLAN20) while filtering out any other VLANs, the following must be configured:
 
Switch together '''ether1''' and '''ether2''':
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
</pre>


Set the switch to filter VLANs based on service tag (0x88a8):
<pre>
<pre>
/interface vlan
/interface ethernet switch
add name=vlan200 interface=ether2 vlan-id=200
set bridge-type=service-vid-used-as-lookup-vid
add name=vlan300 interface=ether2 vlan-id=300
</pre>
add name=vlan400 interface=ether2 vlan-id=400


/ip address
Add a service tag SVID 20 to packets that have a CVID 10 tag on '''ether1''':
add address=192.168.20.1/24 interface=vlan200 network=192.168.20.0
<pre>
add address=192.168.30.1/24 interface=vlan300 network=192.168.30.0
/interface ethernet switch ingress-vlan-translation
add address=192.168.40.1/24 interface=vlan400 network=192.168.40.0
add customer-vid=10 new-service-vid=20 ports=ether1
</pre>
</pre>


* VLAN membership is defined by the VLAN table. Adding entries with VLAN id and ports makes that VLAN traffic valid on those ports. After valid VLAN configuration unknown/invalid VLAN forwarding can be disabled in global switch settings.
Specify '''ether2''' as the tagged/trunk port for SVID 20:
<pre>
/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=20
</pre>


Allow '''ether1''' and '''ether2''' to forward SVID 20:
<pre>
<pre>
/interface ethernet switch vlan
/interface ethernet switch vlan
add ports=switch1-cpu,ether6 vlan-id=200 learn=yes
add ports=ether1,ether2 vlan-id=20
add ports=switch1-cpu,ether7 vlan-id=300 learn=yes
</pre>
add ports=switch1-cpu,ether8 vlan-id=400 learn=yes
 
Override the SVID EtherType (0x88a8) to CVID EtherType (0x8100) on '''ether2''':
<pre>
/interface ethernet switch port
set ether2 egress-service-tpid-override=0x8100 ingress-service-tpid-override=0x8100
</pre>


Enable unknown/invalid VLAN filtering:
<pre>
/interface ethernet switch
/interface ethernet switch
set forward-unknown-vlan=no
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether1,ether2
</pre>
</pre>


===Mirroring===
{{ Note | Since the switch is set to look up VLAN ID based on service tag, which is overridden with a different EtherType, then VLAN filtering is only done on the outer tag of a packet, the inner tag is not checked. }}
 
=Mirroring=


[[File:Mirroring.png|center|frame|alt=Alt text|Mirroring]]
[[File:Mirroring.png|center|frame|alt=Alt text|Mirroring]]
Line 193: Line 473:
The Cloud Router Switches support three types of mirroring. Port based mirroring can be applied to any of switch-chip ports, VLAN based mirroring works for all specified VLANs regardless switch-chip ports and MAC based mirroring copies traffic sent or received from specific device reachable from the port configured in Unicast Forwarding Database.
The Cloud Router Switches support three types of mirroring. Port based mirroring can be applied to any of switch-chip ports, VLAN based mirroring works for all specified VLANs regardless switch-chip ports and MAC based mirroring copies traffic sent or received from specific device reachable from the port configured in Unicast Forwarding Database.


====Port Based Mirroring====
==Port Based Mirroring==


The first configuration sets ether5 port as a mirror0 analyzer port for both ingress and egress mirroring, mirrored traffic will be sent to this port. Port based ingress and egress mirroring is enabled from ether7 port.
The first configuration sets ether5 port as a mirror0 analyzer port for both ingress and egress mirroring, mirrored traffic will be sent to this port. Port based ingress and egress mirroring is enabled from ether6 port.


<pre>
<pre>
/interface ethernet switch
/interface ethernet switch
set ingress-mirror0=ether8 egress-mirror0=ether8
set ingress-mirror0=ether5 egress-mirror0=ether5


/interface ethernet switch port
/interface ethernet switch port
set ether7 egress-mirror-to=mirror0 ingress-mirror-to=mirror0
set ether6 ingress-mirror-to=mirror0 egress-mirror-to=mirror0
</pre>
</pre>


====VLAN Based Mirroring====
==VLAN Based Mirroring==


The second example requires ports to be switched in a group.  Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from VLAN occurs. VLAN table entry enables mirroring only for VLAN 300 traffic between ether2 and ether7 ports.
The second example requires ports to be switched in a group.  Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from VLAN occurs. VLAN table entry enables mirroring only for VLAN 300 traffic between ether2 and ether7 ports.


<pre>
<pre>
/interface ethernet
/interface bridge
set ether7 master-port=ether2
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether7 hw=yes


/interface ethernet switch
/interface ethernet switch
Line 220: Line 503:
</pre>
</pre>


====MAC Based Mirroring====
==MAC Based Mirroring==


The third configuration also requires ports to be switched in a group.  Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from Unicast Forwarding database occurs. The entry from Unicast Forwarding database enables mirroring for packets with source or destination MAC address E7:16:34:A1:CD:18 from ether8 port.
The third configuration also requires ports to be switched in a group.  Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from Unicast Forwarding database occurs. The entry from Unicast Forwarding database enables mirroring for packets with source or destination MAC address E7:16:34:A1:CD:18 from ether8 port.


<pre>
<pre>
/interface ethernet
/interface bridge
set ether8 master-port=ether2
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether8 hw=yes


/interface ethernet switch
/interface ethernet switch
Line 234: Line 520:
add port=ether8 mirror=yes svl=yes mac-address=E7:16:34:A1:CD:18
add port=ether8 mirror=yes svl=yes mac-address=E7:16:34:A1:CD:18
</pre>
</pre>
=Trunking=
[[File:Trunking3.png|center|frame|alt=Alt text|Trunking]]
The Trunking in the Cloud Router Switches provides static link aggregation groups with hardware automatic failover and load balancing.  IEEE802.3ad and IEEE802.1ax compatible Link Aggregation Control Protocol is not supported yet. Up to 8 Trunk groups are supported with up to 8 Trunk member ports per Trunk group.
Configuration requires a group of switched ports and an entry in the Trunk table:
<pre>
/interface bridge
add name=bridge1 protocol-mode=none
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
/interface ethernet switch trunk
add name=trunk1 member-ports=ether6,ether7,ether8
</pre>
This example also shows proper bonding configuration in RouterOS on the other end:
<pre>
/interface bonding
add name=bonding1 slaves=ether2,ether3,ether4 mode=balance-xor transmit-hash-policy=layer-2-and-3 \
link-monitoring=mii mii-interval=100ms
</pre>
{{ Note | You can find a working example for trunking and port based VLANs at [[Manual:CRS_VLANs_with_Trunks | CRS VLANs with Trunks]] page.}}
{{ Warning | Bridge (R)STP is not aware of underlying switch trunking configuration and some trunk ports can move to discarding or blocking state. When trunking member ports are connected to other bridges, you should either disable the (R)STP or filter out any BPDU between trunked devices (e.g. with [[Manual:CRS1xx/2xx_series_switches#Access_Control_List | ACL rules]]).}}
=Limited MAC Access per Port=
Disabling MAC learning and configuring static MAC addresses gives ability to control what exact devices can communicate to CRS1xx/2xx switches and through them.
Configuration requires a group of switched ports, disabled MAC learning on those ports and static UFDB entries:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes learn=no unknown-unicast-flood=no
add bridge=bridge1 interface=ether7 hw=yes learn=no unknown-unicast-flood=no
/interface ethernet switch unicast-fdb
add mac-address=4C:5E:0C:00:00:01 port=ether6 svl=yes
add mac-address=D4:CA:6D:00:00:02 port=ether7 svl=yes
/interface ethernet switch acl
add action=drop src-mac-addr-state=sa-not-found src-ports=ether6,ether7 table=egress
</pre>
CRS1xx/2xx switches also allow to learn one dynamic MAC per port to ensure only one end user device is connected no matter of its MAC address:
<pre>
/interface ethernet switch port
set ether6 learn-limit=1
set ether7 learn-limit=1
</pre>
{{Note | Prior to RouterOS v6.42 MAC learning on ports was configured using property <var>learn-override</var> under <code>/interface ethernet switch port</code> menu.}}
=Isolation=
==Port Level Isolation==
[[File:Port-level-Isolation.png|center|frame|alt=Alt text|Port Level Isolation]]
Port-level isolation is often used for Private VLAN, where:
* One or multiple uplink ports are shared among all users for accessing gateway or router.
* Port group Isolated Ports is for guest users. Communication is through the uplink ports only.
* Port group Community 0 is for department A. Communication is allowed between the group members and through uplink ports.
* Port group Community X is for department X. Communication is allowed between the group members and through uplink ports.
The Cloud Router Switches use port-level isolation profiles for Private VLAN implementation:
* Uplink ports – Port-level isolation profile 0
* Isolated ports – Port-level isolation profile 1
* Community 0 ports - Port-level isolation profile 2
* Community X (X <= 30) ports - Port-level isolation profile X
'''This example requires a group of switched ports. Assume that all ports used in this example are in one switch group.'''
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
add bridge=bridge1 interface=ether9 hw=yes
add bridge=bridge1 interface=ether10 hw=yes
</pre>
The first part of port isolation configuration is setting the Uplink port – set port profile to 0 for ether2:
<pre>
/interface ethernet switch port
set ether2 isolation-leakage-profile-override=0
</pre>
Then continue with setting isolation profile 1 to all isolated ports and adding the communication port for port isolation profile 1:
<pre>
/interface ethernet switch port
set ether5 isolation-leakage-profile-override=1
set ether6 isolation-leakage-profile-override=1
/interface ethernet switch port-isolation
add port-profile=1 ports=ether2 type=dst
</pre>
Configuration to set Community 2 and Community 3 ports is similar:
<pre>
/interface ethernet switch port
set ether7 isolation-leakage-profile-override=2
set ether8 isolation-leakage-profile-override=2
/interface ethernet switch port-isolation
add port-profile=2 ports=ether2,ether7,ether8 type=dst
/interface ethernet switch port
set ether9 isolation-leakage-profile-override=3
set ether10 isolation-leakage-profile-override=3
/interface ethernet switch port-isolation
add port-profile=3 ports=ether2,ether9,ether10 type=dst
</pre>
==Protocol Level Isolation==
[[File:Protocol-level-Isolation.png|center|frame|alt=Alt text|Protocol Level Isolation]]
Protocol level isolation on CRS switches can be used to enchance network security. For example, restricting DHCP traffic between the users and allowing it only to trusted DHCP server port can prevent security risks like DHCP spoofing attack.
The following example shows how to configure it on CRS.
Switch together the required ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether5 hw=yes
</pre>
Set the same Community port profile for all DHCP client ports. Community port profile numbers are from 2 to 30.
<pre>
/interface ethernet switch port
set ether2 isolation-leakage-profile-override=2
set ether3 isolation-leakage-profile-override=2
set ether4 isolation-leakage-profile-override=2
set ether5 isolation-leakage-profile-override=2
</pre>
And configure port isolation/leakage profile for selected Community (2) to allow DHCP traffic destined only to port where the trusted DHCP server is located. <var>registration-status</var> and <var>traffic-type</var> properties have to be set empty in order to apply restriction only for DHCP protocol.
<pre>
/interface ethernet switch port-isolation
add port-profile=2 protocol-type=dhcpv4 type=dst forwarding-type=bridged ports=ether1 \
registration-status="" traffic-type=""
</pre>
=Quality of Service (QoS)=
<b>QoS configuration schemes</b>
MAC based traffic scheduling and shaping:
[MAC address in UFDB] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]
VLAN based traffic scheduling and shaping:
[VLAN id in VLAN table] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]
Protocol based traffic scheduling and shaping:
[Protocol in Protocol VLAN table] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]
PCP/DEI based traffic scheduling and shaping:
[Switch port PCP/DEI mapping] -> [Priority] -> [Queue] -> [Shaper]
DSCP based traffic scheduling and shaping:
[QoS DSCP mapping] -> [Priority] -> [Queue] -> [Shaper]
==MAC based traffic scheduling using internal Priority==
In Strict Priority scheduling mode, the highest priority queue is served first.
The queue number represents the priority and the queue with highest queue number has the highest priority.
Traffic is transmitted from highest priority queue until the queue is empty, and then moves to the next highest priority queue, and so on.
If no congestion is present on the egress port, packet is transmitted as soon as it is received.
If congestion occurs on the port where high priority traffics keep coming, the lower priority queues starve.
On all CRS switches the scheme where MAC based egress traffic scheduling is done according to internal Priority would be following: [MAC address] -> [QoS Group] -> [Priority] -> [Queue];<br />
In this example host1 (E7:16:34:00:00:01) and host2 (E7:16:34:00:00:02) will have higher priority 1 and the rest of the hosts will have lower priority 0 for transmited traffic on port ether7.
Note that CRS has maximum 8 queues per port.
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
Create QoS group for use in UFDB:
<pre>
/interface ethernet switch qos-group
add name=group1 priority=1
</pre>
Add UFDB entries to match specific MACs on ether7 and apply QoS group1:
<pre>
/interface ethernet switch unicast-fdb
add mac-address=E7:16:34:00:00:01 port=ether7 qos-group=group1 svl=yes
add mac-address=E7:16:34:00:00:02 port=ether7 qos-group=group1 svl=yes
</pre>
Configure ether7 port queues to work according Strict Priority and QoS scheme only for destination address:
<pre>
/interface ethernet switch port
set ether7 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1 \
    qos-scheme-precedence=da-based
</pre>
==MAC based traffic shaping using internal Priority==
The scheme where MAC based traffic shaping is done according to internal Priority would be following: [MAC address] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper];<br />
In this example unlimited traffic will have priority 0 and limited traffic will have priority 1 with the bandwidth limit 10Mbit.
Note that CRS has maximum 8 queues per port.
Create a group of ports for switching:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
Create QoS group for use in UFDB:
<pre>
/interface ethernet switch qos-group
add name=group1 priority=1
</pre>
Add UFDB entry to match specific MAC on ether8 and apply QoS group1:
<pre>
/interface ethernet switch unicast-fdb
add mac-address=E7:16:34:A1:CD:18 port=ether8 qos-group=group1 svl=yes
</pre>
Configure ether8 port queues to work according Strict Priority and QoS scheme only for destination address:
<pre>
/interface ethernet switch port
set ether8 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1 \
    qos-scheme-precedence=da-based
</pre>
Apply bandwidth limit for queue1 on ether8:
<pre>
/interface ethernet switch shaper
add port=ether8 rate=10M target=queue1
</pre>
If CRS switch supports Access Control List, this configuration is simpler:
<pre>
/interface ethernet switch acl policer
add name=policer1 yellow-burst=100k yellow-rate=10M
/interface ethernet switch acl
add mac-dst-address=E7:16:34:A1:CD:18 policer=policer1
</pre>
==VLAN based traffic scheduling + shaping using internal Priorities==
Best practice is to assign lower internal QoS Priority for traffic limited by shaper to make it also less important in Strict Priority scheduler.
(higher priority should be more important and unlimited)
In this example:<br />
Switch port ether6 is using shaper to limit the traffic that comes from ether7 and ether8.<br />
When link has reached its capacity, the traffic with the highest priority will be sent out first.<br />
VLAN10 -> QoS group0 = lowest priority<br />
VLAN20 -> QoS group1 = normal priority<br />
VLAN30 -> QoS group2 = highest priority<br />
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
</pre>
Create QoS groups for use in VLAN table.
<pre>
/interface ethernet switch qos-group
add name=group0 priority=0
add name=group1 priority=1
add name=group2 priority=2
</pre>
Add VLAN entries to apply QoS groups for certain VLANs.
<pre>
/interface ethernet switch vlan
add ports=ether6,ether7,ether8 qos-group=group0 vlan-id=10
add ports=ether6,ether7,ether8 qos-group=group1 vlan-id=20
add ports=ether6,ether7,ether8 qos-group=group2 vlan-id=30
</pre>
Configure ether6, ether7, ether8 port queues to work according Strict Priority and QoS scheme only for VLAN based QoS.
<pre>
/interface ethernet switch port
set ether6 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based
set ether7 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based
set ether8 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based
</pre>
Apply bandwidth limit on ether6.
<pre>
/interface ethernet switch shaper
add port=ether6 rate=10M
</pre>
==PCP based traffic scheduling==
By default CRS1xx/CRS2xx series devices will ignore the PCP/CoS/802.1p value and forward packets based on FIFO (First-In-First-Out) manner. When the device's internal queue is not full, then packets are in FIFO manner, but as soon as a queue is filled, then higher priority traffic can be sent out first. Lets consider a scenario when '''ether1''' and '''ether2''' is forwarding data to '''ether3''', but when '''ether3''' is congested, then packets are going to be scheduled, we can configure the switch to hold lowest priority packets until all higher priority packets are sent out, this is a very common scenario for VoIP type setups, where some traffic needs to be prioritized.
To achieve such a behaviour, switch together '''ether1''', '''ether2''' and '''ether3''' ports:
<pre>
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes
</pre>
Enable '''Strict Policy''' for each internal queue on each port:
<pre>
/interface ethernet switch port
set ether1,ether2,ether3 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0"
</pre>
Map each PCP value to an internal priority value, for convenience reasons simply map PCP to an internal priority 1-to-1:
<pre>
/interface ethernet switch port
set ether1,ether2,ether3 pcp-based-qos-priority-mapping=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7
</pre>
Since the switch will empty the largest queue first and you need the highest priority to be served first, then you can assign this internal priority to a queue 1-to-1:
<pre>
/interface ethernet switch port
set ether1,ether2,ether3 priority-to-queue=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7
</pre>
Finally, set each switch port to schedule packets based on the PCP value:
<pre>
/interface ethernet switch port
set ether1,ether2,ether3 qos-scheme-precedence=pcp-based
</pre>
=Bandwidth Limiting=
Both Ingress Port policer and Shaper provide bandwidth limiting features for CRS switches.
* Ingress Port Policer sets RX limit on port:
<pre>
/interface ethernet switch ingress-port-policer
add port=ether5 meter-unit=bit rate=10M
</pre>
* Shaper sets TX limit on port:
<pre>
/interface ethernet switch shaper
add port=ether5 meter-unit=bit rate=10M
</pre>
=Traffic Storm Control=
The same Ingress Port policer also can be used for the traffic storm control to prevent disruptions on Layer 2 ports caused by broadcast, multicast or unicast traffic storms.
* Broadcast storm control example on ether5 port with 500 packet limit per second:
<pre>
/interface ethernet switch ingress-port-policer
add port=ether5 rate=500 meter-unit=packet packet-types=broadcast
</pre>
* Example with multiple packet types which includes ARP and ND protocols and unregistered multicast traffic. Unregistered multicast is traffic which is not defined in Multicast Forwarding database.
<pre>
/interface ethernet switch ingress-port-policer
add port=ether5 rate=5k meter-unit=packet packet-types=broadcast,arp-or-nd,unregistered-multicast
</pre>
=See also=
* [[Manual:CRS1xx/2xx_series_switches | CRS1xx/2xx series switches]]
* [[Manual:CRS_Router | CRS Router]]
* [[Manual:CRS1xx/2xx_VLANs_with_Trunks | CRS1xx/2xx VLANs with Trunks]]
* [[Manual:Basic_VLAN_switching | Basic VLAN switching]]
* [[Manual:Interface/Bridge#Bridge_Hardware_Offloading | Bridge Hardware Offloading]]
* [[Manual:Interface/Bridge#Spanning_Tree_Protocol | Spanning Tree Protocol]]
* [[Manual:Interface/Bridge#IGMP_Snooping | IGMP Snooping]]
* [[Manual:Interface/Bridge#DHCP_Snooping_and_DHCP_Option_82 | DHCP Snooping and Option 82]]
* [[M:Maximum_Transmission_Unit_on_RouterBoards | MTU on RouterBOARD]]
* [[Manual:Layer2_misconfiguration | Layer2 misconfiguration]]
* [[Manual:Master-port | Master-port]]


{{cont}}
{{cont}}


[[Category:Manual]]
[[Category:Bridging and switching]]
[[Category:Interface|Switch Chip Features]]
[[Category:Examples]]
[[Category:Case Studies|Switch Chip Features]]
[[Category:Routerboard|Switch Chip Features]]

Latest revision as of 10:02, 17 January 2022

Applies to RouterOS: v6.41 +

Warning: This manual is moved to [CRS1xx/2xx series switches examples]



Summary

Basic use cases and configuration examples for Cloud Router Switch features.

Warning: This article applies to CRS1xx and CRS2xx series switches and not to CRS3xx series switches. For CRS3xx series devices read the CRS3xx series switches manual.


Port switching

In order to setup port switching on CRS1xx/2xx series switches, check the Bridge Hardware Offloading page.

Warning: It is possible to create multiple isolated switch group by using multiple bridges with enabled hardware offloading, this is possible only on CRS1xx/2xx series switches. For more complex setups (for example, VLAN filtering) you should use the port isolation feature instead.


Note: Port switching in RouterOS v6.41 and newer is done using the bridge configuration. Prior to RouterOS v6.41 port switching was done using the master-port property, for more details check the Master-port page.


Management access configuration

In general, switches are only supposed to forward packets by using the built-in switch chip, but not allow access to the device itself for security reasons. It is possible to use device's serial port for management access, but in most cases such an access method is not desired and access using an IP address is more suitable. In such cases you will need to configure management access.

In all types of management access it is assumed that ports must be switched together, use the following commands to switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether5 hw=yes

You should also assign an IP address to the bridge interface so the device is reachable using an IP address (the device is also reachable using a MAC address):

/ip address
add address=192.168.88.1/24 interface=bridge1

Untagged

If invalid VLAN filtering is not enabled, management access to the device using tagged or untagged (VLAN 0) traffic is already allowed from any port, though this is not a good practice, this can cause security issues and can cause the device's CPU to be overloaded in certain situations (most commonly with broadcast type of traffic).

If you are intending to use invalid VLAN filtering (which you should), then ports, from which you are going to access the switch, must to be added to the VLAN table for untagged (VLAN 0) traffic, for example, in case you want to access the switch from ether2:

/interface ethernet switch vlan
add vlan-id=0 ports=ether2,switch1-cpu 

Tagged

Allowing only tagged traffic to have management access to the device through a specific port is a much better practice. For example, to allow only VLAN99 to access the device through ether2 you should first add an entry to the VLAN table, which will allow the selected port and the CPU port (switch1-cpu) to forward the selected VLAN ID, therefore allowing management access:

/interface ethernet switch vlan
add ports=ether2,switch1-cpu vlan-id=99

Packets that will be sent out from the CPU, for example, ping replies will not have a VLAN tag, to solve this you need to specify which ports should always send out packets with a VLAN tag for a specific VLAN ID:

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2,switch1-cpu vlan-id=99

After valid VLAN99 configuration has been setup, you can enable unknown/invalid VLAN filtering, which will not allow the management access through different ports than specified in the VLAN table:

/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether3,ether4,ether5

In this example VLAN99 will be used to access the device, a VLAN interface on the bridge must be created and an IP address must be assigned to it.

/interface vlan
add interface=bridge1 name=MGMT vlan-id=99
/ip address
add address=192.168.99.1/24 interface=MGMT

VLAN

Note: It is recommended to get Serial Console cable and test it before configuring VLANs because you may lose access to the CPU and/or the port you are connected to.


Note: Some changes may take some time to take effect due to already learned MAC addreses. In such cases flushing Unicast Forwarding Database can help: /interface ethernet switch unicast-fdb flush


Warning: Multiple hardware offloaded bridge configuration is designed as fast and simple port isolation solution, but it limits part of VLAN functionality supported by CRS switch-chip. For advanced configurations use one bridge within CRS switch chip for all ports, configure VLANs and isolate port groups with port isolation profile configuration.


Port Based VLAN

Note: For CRS3xx series devices you must use bridge VLAN filtering, you can read more about it in the Bridge VLAN Filtering section.


Example 1 (Trunk and Access ports)

Alt text
Port Based VLAN 1

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Specify the VLAN ID that the switch must set on untagged (VLAN0) traffic for each access port:

/interface ethernet switch ingress-vlan-translation
add ports=ether6 customer-vid=0 new-customer-vid=200
add ports=ether7 customer-vid=0 new-customer-vid=300
add ports=ether8 customer-vid=0 new-customer-vid=400

Note: When an entry is created under /interface ethernet switch ingress-vlan-translation, then the switch chip will add a VLAN tag on ingress frames on the specified port. To remove the VLAN tag on the same port for egress frames, an /interface ethernet switch egress-vlan-tag entry should be created for the same VLAN ID where only tagged ports are specified. If specific VLAN is forwarded only between access ports, the /interface ethernet switch egress-vlan-tag entry should still be created without any tagged ports. Another option is to create extra entries under /interface ethernet switch egress-vlan-translation menu to set untagged (VLAN0) traffic.


You must also specify which VLANs should be sent out the trunk port with a VLAN tag. Use the tagged-ports property to setup a trunk port:

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=200
add tagged-ports=ether2 vlan-id=300
add tagged-ports=ether2 vlan-id=400

Add entries to the VLAN table to specify VLAN memberships for each port and each VLAN ID:

/interface ethernet switch vlan
add ports=ether2,ether6 vlan-id=200
add ports=ether2,ether7 vlan-id=300
add ports=ether2,ether8 vlan-id=400

After valid VLAN configuration has been setup, you can enable unknown/invalid VLAN filtering:

/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8

Note: It is possible to use the built-in switch chip and the CPU at the same time to create a Switch-Router setup, where a device acts as a switch and as a router at the same time. You can find a configuration example in the CRS-Router guide.


Example 2 (Trunk and Hybrid ports)

Alt text
Port Based VLAN 2

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Specify the VLAN ID that the switch must set on untagged (VLAN0) traffic for each access port:

/interface ethernet switch ingress-vlan-translation
add ports=ether6 customer-vid=0 new-customer-vid=200
add ports=ether7 customer-vid=0 new-customer-vid=300
add ports=ether8 customer-vid=0 new-customer-vid=400

By specifying ports as tagged-ports, the switch will always send out packets as tagged packets with the corresponding VLAN ID. Add appropriate entries according to the diagram above:

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2,ether7,ether8 vlan-id=200
add tagged-ports=ether2,ether6,ether8 vlan-id=300
add tagged-ports=ether2,ether6,ether7 vlan-id=400

Add entries to the VLAN table to specify VLAN memberships for each port and each VLAN ID:

/interface ethernet switch vlan
add ports=ether2,ether6,ether7,ether8 vlan-id=200 learn=yes
add ports=ether2,ether6,ether7,ether8 vlan-id=300 learn=yes
add ports=ether2,ether6,ether7,ether8 vlan-id=400 learn=yes

After valid VLAN configuration has been setup, you can enable unknown/invalid VLAN filtering:

/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8

Protocol Based VLAN

Alt text
Protocol Based VLAN

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Set VLAN for IP and ARP protocols:

/interface ethernet switch protocol-based-vlan
add port=ether2 protocol=arp set-customer-vid-for=all new-customer-vid=0
add port=ether6 protocol=arp set-customer-vid-for=all new-customer-vid=200
add port=ether2 protocol=ip set-customer-vid-for=all new-customer-vid=0
add port=ether6 protocol=ip set-customer-vid-for=all new-customer-vid=200

Set VLAN for IPX protocol:

/interface ethernet switch protocol-based-vlan
add port=ether2 protocol=ipx set-customer-vid-for=all new-customer-vid=0
add port=ether7 protocol=ipx set-customer-vid-for=all new-customer-vid=300

Set VLAN for AppleTalk AARP and AppleTalk DDP protocols:

/interface ethernet switch protocol-based-vlan
add port=ether2 protocol=0x80F3 set-customer-vid-for=all new-customer-vid=0
add port=ether8 protocol=0x80F3 set-customer-vid-for=all new-customer-vid=400
add port=ether2 protocol=0x809B set-customer-vid-for=all new-customer-vid=0
add port=ether8 protocol=0x809B set-customer-vid-for=all new-customer-vid=400

MAC Based VLAN

Warning: Internally all MAC addresses in MAC based VLANs are hashed, certain MAC addresses can have the same hash, which will prevent a MAC address being loaded in to the switch chip if the hash matches with a hash from a MAC address that has been already loaded, for this reason it is recommended to use Port bases VLANs in combination with MAC based VLANs. This is a hardware limitation.


Alt text
MAC Based VLAN

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether7 hw=yes

Enable MAC based VLAN translation on access port:

/interface ethernet switch port
set ether7 allow-fdb-based-vlan-translate=yes

Add MAC-to-VLAN mapping entries in MAC based VLAN table:

/interface ethernet switch mac-based-vlan
add src-mac=A4:12:6D:77:94:43 new-customer-vid=200
add src-mac=84:37:62:DF:04:20 new-customer-vid=300
add src-mac=E7:16:34:A1:CD:18 new-customer-vid=400

Add VLAN200, VLAN300 and VLAN400 tagging on ether2 port to create it as VLAN trunk port:

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=200
add tagged-ports=ether2 vlan-id=300
add tagged-ports=ether2 vlan-id=400

Additionally, add entries to the VLAN table, specify VLAN membership for each port and enable unknown/invalid VLAN filtering, see an example below - Unknown/Invalid VLAN filtering. This is required for network setups where more interfaces are added to the bridge, as it allows to define VLAN boundaries.

InterVLAN Routing

Alt text
InterVLAN Routing

InterVLAN routing configuration consists of two main parts – VLAN tagging in switch-chip and routing in RouterOS. This configuration can be used in many applications by combining it with DHCP server, Hotspot, PPP and other features for each VLAN.

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Set VLAN tagging on CPU port for all VLANs to make packets tagged before they are routed:

/interface ethernet switch egress-vlan-tag
add tagged-ports=switch1-cpu vlan-id=200
add tagged-ports=switch1-cpu vlan-id=300
add tagged-ports=switch1-cpu vlan-id=400

add ingress VLAN translation rules to ensure that the correct VLAN ID assignment is done on access ports:

/interface ethernet switch ingress-vlan-translation
add ports=ether6 customer-vid=0 new-customer-vid=200
add ports=ether7 customer-vid=0 new-customer-vid=300
add ports=ether8 customer-vid=0 new-customer-vid=400

Create the VLAN interfaces on top of the bridge interface:

/interface vlan
add name=VLAN200 interface=bridge1 vlan-id=200
add name=VLAN300 interface=bridge1 vlan-id=300
add name=VLAN400 interface=bridge1 vlan-id=400

Warning: Make sure the VLAN interfaces are created on top of the bridge interface instead of any of the physical interfaces. If the VLAN interfaces are created on a slave interface, then packet might not be received correctly and therefore routing might fail. More detailed information can be found in the VLAN interface on a slave interface manual page.


Add IP addresses to created the VLAN interfaces. In this example, three 192.168.x.1 addresses are added to VLAN200, VLAN300 and VLAN400 interfaces:

/ip address
add address=192.168.20.1/24 interface=VLAN200
add address=192.168.30.1/24 interface=VLAN300
add address=192.168.40.1/24 interface=VLAN400

Unknown/Invalid VLAN filtering

VLAN membership is defined in the VLAN table. Adding entries with VLAN ID and ports makes that VLAN traffic valid on those ports. After valid VLAN configuration has been setup, unknown/invalid VLAN filtering can be enabled. This VLAN filtering configuration example applies to InterVLAN Routing setup.

/interface ethernet switch vlan
add ports=switch1-cpu,ether6 vlan-id=200
add ports=switch1-cpu,ether7 vlan-id=300
add ports=switch1-cpu,ether8 vlan-id=400
  • Option 1: disable invalid VLAN forwarding on specific ports (more common):
/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether2,ether6,ether7,ether8
  • Option 2: disable invalid VLAN forwarding on all ports:
/interface ethernet switch
set forward-unknown-vlan=no

Warning: Using multiple bridges on a single switch chip with enabled unknown/invalid VLAN filtering can cause unexpected behavior. You should always use a single bridge configuration whenever using VLAN filtering. If port isolation is required, then port isolation feature should be used instead of using multiple bridges.


VLAN Tunneling (Q-in-Q)

This example covers typical VLAN tunneling use case where service provider devices add another VLAN tag for independent forwarding in the mean time allowing customers to use their own VLANs.

Note: This example contains only Service VLAN tagging part.
It is recommended to additionally set Unknown/Invalid VLAN filtering configuration on ports.


Alt text
Q-in-Q VLAN


CRS-1: The first switch on the edge of service provider network has to properly indentify traffic from customer VLAN id on port and assign new service VLAN id with ingress VLAN translation rules.

VLAN trunk port configuration for service provider VLAN tags is in the same egress-vlan-tag table.

The main difference from basic Port Based VLAN configuration is that CRS switch-chip has to be set to do forwarding according to service (outer) VLAN id instead of customer (inner) VLAN id.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether9 hw=yes

/interface ethernet switch ingress-vlan-translation
add customer-vid=200 new-service-vid=400 ports=ether1
add customer-vid=300 new-service-vid=500 ports=ether2

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether9 vlan-id=400
add tagged-ports=ether9 vlan-id=500

/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid

CRS-2: The second switch in the service provider network require only switched ports to do forwarding according to service (outer) VLAN id instead of customer (inner) VLAN id.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether9 hw=yes
add bridge=bridge1 interface=ether10 hw=yes

/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid

CRS-3: The third switch has similar configuration to CRS-1:

  • Ports in a switch group using a bridge;
  • Ingress VLAN translation rules to define new service VLAN assingments on ports;
  • tagged-ports for service provider VLAN trunks;
  • CRS switch-chip set to use service VLAN id in switching lookup.
/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether10 hw=yes

/interface ethernet switch ingress-vlan-translation
add customer-vid=200 new-service-vid=400 ports=ether3
add customer-vid=300 new-service-vid=500 ports=ether4

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether10 vlan-id=400
add tagged-ports=ether10 vlan-id=500

/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid

CVID Stacking

It is possible to use CRS1xx/CRS2xx series switches for CVID Stacking setups. CRS1xx/CRS2xx series switches are capable of VLAN filtering based on the outer tag of tagged packets that have two CVID tags (double CVID tag), these switches are also capable of adding another CVID tag on top of an existing CVID tag (CVID Stacking). For example, in a setup where ether1 is receiving tagged packets with CVID 10, but it is required that ether2 sends out these packets with another tag CVID 20 (VLAN10 inside VLAN20) while filtering out any other VLANs, the following must be configured:

Switch together ether1 and ether2:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes

Set the switch to filter VLANs based on service tag (0x88a8):

/interface ethernet switch
set bridge-type=service-vid-used-as-lookup-vid

Add a service tag SVID 20 to packets that have a CVID 10 tag on ether1:

/interface ethernet switch ingress-vlan-translation
add customer-vid=10 new-service-vid=20 ports=ether1

Specify ether2 as the tagged/trunk port for SVID 20:

/interface ethernet switch egress-vlan-tag
add tagged-ports=ether2 vlan-id=20

Allow ether1 and ether2 to forward SVID 20:

/interface ethernet switch vlan
add ports=ether1,ether2 vlan-id=20

Override the SVID EtherType (0x88a8) to CVID EtherType (0x8100) on ether2:

/interface ethernet switch port
set ether2 egress-service-tpid-override=0x8100 ingress-service-tpid-override=0x8100

Enable unknown/invalid VLAN filtering:

/interface ethernet switch
set drop-if-invalid-or-src-port-not-member-of-vlan-on-ports=ether1,ether2

Note: Since the switch is set to look up VLAN ID based on service tag, which is overridden with a different EtherType, then VLAN filtering is only done on the outer tag of a packet, the inner tag is not checked.


Mirroring

Alt text
Mirroring

The Cloud Router Switches support three types of mirroring. Port based mirroring can be applied to any of switch-chip ports, VLAN based mirroring works for all specified VLANs regardless switch-chip ports and MAC based mirroring copies traffic sent or received from specific device reachable from the port configured in Unicast Forwarding Database.

Port Based Mirroring

The first configuration sets ether5 port as a mirror0 analyzer port for both ingress and egress mirroring, mirrored traffic will be sent to this port. Port based ingress and egress mirroring is enabled from ether6 port.

/interface ethernet switch
set ingress-mirror0=ether5 egress-mirror0=ether5

/interface ethernet switch port
set ether6 ingress-mirror-to=mirror0 egress-mirror-to=mirror0

VLAN Based Mirroring

The second example requires ports to be switched in a group. Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from VLAN occurs. VLAN table entry enables mirroring only for VLAN 300 traffic between ether2 and ether7 ports.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether7 hw=yes

/interface ethernet switch
set ingress-mirror0=ether5 vlan-uses=mirror0

/interface ethernet switch vlan
add ports=ether2,ether7 vlan-id=300 learn=yes ingress-mirror=yes

MAC Based Mirroring

The third configuration also requires ports to be switched in a group. Mirroring configuration sets ether5 port as a mirror0 analyzer port and sets mirror0 port to be used when mirroring from Unicast Forwarding database occurs. The entry from Unicast Forwarding database enables mirroring for packets with source or destination MAC address E7:16:34:A1:CD:18 from ether8 port.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

/interface ethernet switch
set ingress-mirror0=ether5 fdb-uses=mirror0

/interface ethernet switch unicast-fdb
add port=ether8 mirror=yes svl=yes mac-address=E7:16:34:A1:CD:18

Trunking

Alt text
Trunking

The Trunking in the Cloud Router Switches provides static link aggregation groups with hardware automatic failover and load balancing. IEEE802.3ad and IEEE802.1ax compatible Link Aggregation Control Protocol is not supported yet. Up to 8 Trunk groups are supported with up to 8 Trunk member ports per Trunk group.

Configuration requires a group of switched ports and an entry in the Trunk table:

/interface bridge
add name=bridge1 protocol-mode=none
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

/interface ethernet switch trunk
add name=trunk1 member-ports=ether6,ether7,ether8

This example also shows proper bonding configuration in RouterOS on the other end:

/interface bonding
add name=bonding1 slaves=ether2,ether3,ether4 mode=balance-xor transmit-hash-policy=layer-2-and-3 \
link-monitoring=mii mii-interval=100ms

Note: You can find a working example for trunking and port based VLANs at CRS VLANs with Trunks page.


Warning: Bridge (R)STP is not aware of underlying switch trunking configuration and some trunk ports can move to discarding or blocking state. When trunking member ports are connected to other bridges, you should either disable the (R)STP or filter out any BPDU between trunked devices (e.g. with ACL rules).


Limited MAC Access per Port

Disabling MAC learning and configuring static MAC addresses gives ability to control what exact devices can communicate to CRS1xx/2xx switches and through them.

Configuration requires a group of switched ports, disabled MAC learning on those ports and static UFDB entries:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes learn=no unknown-unicast-flood=no
add bridge=bridge1 interface=ether7 hw=yes learn=no unknown-unicast-flood=no

/interface ethernet switch unicast-fdb
add mac-address=4C:5E:0C:00:00:01 port=ether6 svl=yes
add mac-address=D4:CA:6D:00:00:02 port=ether7 svl=yes

/interface ethernet switch acl
add action=drop src-mac-addr-state=sa-not-found src-ports=ether6,ether7 table=egress

CRS1xx/2xx switches also allow to learn one dynamic MAC per port to ensure only one end user device is connected no matter of its MAC address:

/interface ethernet switch port
set ether6 learn-limit=1
set ether7 learn-limit=1

Note: Prior to RouterOS v6.42 MAC learning on ports was configured using property learn-override under /interface ethernet switch port menu.


Isolation

Port Level Isolation

Alt text
Port Level Isolation

Port-level isolation is often used for Private VLAN, where:

  • One or multiple uplink ports are shared among all users for accessing gateway or router.
  • Port group Isolated Ports is for guest users. Communication is through the uplink ports only.
  • Port group Community 0 is for department A. Communication is allowed between the group members and through uplink ports.
  • Port group Community X is for department X. Communication is allowed between the group members and through uplink ports.

The Cloud Router Switches use port-level isolation profiles for Private VLAN implementation:

  • Uplink ports – Port-level isolation profile 0
  • Isolated ports – Port-level isolation profile 1
  • Community 0 ports - Port-level isolation profile 2
  • Community X (X <= 30) ports - Port-level isolation profile X

This example requires a group of switched ports. Assume that all ports used in this example are in one switch group.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes
add bridge=bridge1 interface=ether9 hw=yes
add bridge=bridge1 interface=ether10 hw=yes

The first part of port isolation configuration is setting the Uplink port – set port profile to 0 for ether2:

/interface ethernet switch port
set ether2 isolation-leakage-profile-override=0

Then continue with setting isolation profile 1 to all isolated ports and adding the communication port for port isolation profile 1:

/interface ethernet switch port
set ether5 isolation-leakage-profile-override=1
set ether6 isolation-leakage-profile-override=1

/interface ethernet switch port-isolation
add port-profile=1 ports=ether2 type=dst

Configuration to set Community 2 and Community 3 ports is similar:

/interface ethernet switch port
set ether7 isolation-leakage-profile-override=2
set ether8 isolation-leakage-profile-override=2

/interface ethernet switch port-isolation
add port-profile=2 ports=ether2,ether7,ether8 type=dst

/interface ethernet switch port
set ether9 isolation-leakage-profile-override=3
set ether10 isolation-leakage-profile-override=3

/interface ethernet switch port-isolation
add port-profile=3 ports=ether2,ether9,ether10 type=dst

Protocol Level Isolation

Alt text
Protocol Level Isolation

Protocol level isolation on CRS switches can be used to enchance network security. For example, restricting DHCP traffic between the users and allowing it only to trusted DHCP server port can prevent security risks like DHCP spoofing attack. The following example shows how to configure it on CRS.

Switch together the required ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes
add bridge=bridge1 interface=ether4 hw=yes
add bridge=bridge1 interface=ether5 hw=yes

Set the same Community port profile for all DHCP client ports. Community port profile numbers are from 2 to 30.

/interface ethernet switch port
set ether2 isolation-leakage-profile-override=2
set ether3 isolation-leakage-profile-override=2
set ether4 isolation-leakage-profile-override=2
set ether5 isolation-leakage-profile-override=2

And configure port isolation/leakage profile for selected Community (2) to allow DHCP traffic destined only to port where the trusted DHCP server is located. registration-status and traffic-type properties have to be set empty in order to apply restriction only for DHCP protocol.

/interface ethernet switch port-isolation
add port-profile=2 protocol-type=dhcpv4 type=dst forwarding-type=bridged ports=ether1 \
registration-status="" traffic-type=""

Quality of Service (QoS)

QoS configuration schemes

MAC based traffic scheduling and shaping: [MAC address in UFDB] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]

VLAN based traffic scheduling and shaping: [VLAN id in VLAN table] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]

Protocol based traffic scheduling and shaping: [Protocol in Protocol VLAN table] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper]

PCP/DEI based traffic scheduling and shaping: [Switch port PCP/DEI mapping] -> [Priority] -> [Queue] -> [Shaper]

DSCP based traffic scheduling and shaping: [QoS DSCP mapping] -> [Priority] -> [Queue] -> [Shaper]

MAC based traffic scheduling using internal Priority

In Strict Priority scheduling mode, the highest priority queue is served first. The queue number represents the priority and the queue with highest queue number has the highest priority. Traffic is transmitted from highest priority queue until the queue is empty, and then moves to the next highest priority queue, and so on. If no congestion is present on the egress port, packet is transmitted as soon as it is received. If congestion occurs on the port where high priority traffics keep coming, the lower priority queues starve.

On all CRS switches the scheme where MAC based egress traffic scheduling is done according to internal Priority would be following: [MAC address] -> [QoS Group] -> [Priority] -> [Queue];
In this example host1 (E7:16:34:00:00:01) and host2 (E7:16:34:00:00:02) will have higher priority 1 and the rest of the hosts will have lower priority 0 for transmited traffic on port ether7. Note that CRS has maximum 8 queues per port.

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Create QoS group for use in UFDB:

/interface ethernet switch qos-group
add name=group1 priority=1

Add UFDB entries to match specific MACs on ether7 and apply QoS group1:

/interface ethernet switch unicast-fdb
add mac-address=E7:16:34:00:00:01 port=ether7 qos-group=group1 svl=yes
add mac-address=E7:16:34:00:00:02 port=ether7 qos-group=group1 svl=yes

Configure ether7 port queues to work according Strict Priority and QoS scheme only for destination address:

/interface ethernet switch port
set ether7 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1 \
    qos-scheme-precedence=da-based

MAC based traffic shaping using internal Priority

The scheme where MAC based traffic shaping is done according to internal Priority would be following: [MAC address] -> [QoS Group] -> [Priority] -> [Queue] -> [Shaper];
In this example unlimited traffic will have priority 0 and limited traffic will have priority 1 with the bandwidth limit 10Mbit. Note that CRS has maximum 8 queues per port.

Create a group of ports for switching:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Create QoS group for use in UFDB:

/interface ethernet switch qos-group
add name=group1 priority=1

Add UFDB entry to match specific MAC on ether8 and apply QoS group1:

/interface ethernet switch unicast-fdb
add mac-address=E7:16:34:A1:CD:18 port=ether8 qos-group=group1 svl=yes

Configure ether8 port queues to work according Strict Priority and QoS scheme only for destination address:

/interface ethernet switch port
set ether8 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1 \
    qos-scheme-precedence=da-based

Apply bandwidth limit for queue1 on ether8:

/interface ethernet switch shaper
add port=ether8 rate=10M target=queue1

If CRS switch supports Access Control List, this configuration is simpler:

/interface ethernet switch acl policer
add name=policer1 yellow-burst=100k yellow-rate=10M

/interface ethernet switch acl
add mac-dst-address=E7:16:34:A1:CD:18 policer=policer1

VLAN based traffic scheduling + shaping using internal Priorities

Best practice is to assign lower internal QoS Priority for traffic limited by shaper to make it also less important in Strict Priority scheduler. (higher priority should be more important and unlimited)

In this example:
Switch port ether6 is using shaper to limit the traffic that comes from ether7 and ether8.
When link has reached its capacity, the traffic with the highest priority will be sent out first.
VLAN10 -> QoS group0 = lowest priority
VLAN20 -> QoS group1 = normal priority
VLAN30 -> QoS group2 = highest priority

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether6 hw=yes
add bridge=bridge1 interface=ether7 hw=yes
add bridge=bridge1 interface=ether8 hw=yes

Create QoS groups for use in VLAN table.

/interface ethernet switch qos-group
add name=group0 priority=0
add name=group1 priority=1
add name=group2 priority=2

Add VLAN entries to apply QoS groups for certain VLANs.

/interface ethernet switch vlan
add ports=ether6,ether7,ether8 qos-group=group0 vlan-id=10
add ports=ether6,ether7,ether8 qos-group=group1 vlan-id=20
add ports=ether6,ether7,ether8 qos-group=group2 vlan-id=30

Configure ether6, ether7, ether8 port queues to work according Strict Priority and QoS scheme only for VLAN based QoS.

/interface ethernet switch port
set ether6 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based
set ether7 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based
set ether8 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-prior\
    ity:0,strict-priority:0,strict-priority:0,strict-priority:0" priority-to-queue=0:0,1:1,2:2 \
    qos-scheme-precedence=vlan-based

Apply bandwidth limit on ether6.

/interface ethernet switch shaper
add port=ether6 rate=10M

PCP based traffic scheduling

By default CRS1xx/CRS2xx series devices will ignore the PCP/CoS/802.1p value and forward packets based on FIFO (First-In-First-Out) manner. When the device's internal queue is not full, then packets are in FIFO manner, but as soon as a queue is filled, then higher priority traffic can be sent out first. Lets consider a scenario when ether1 and ether2 is forwarding data to ether3, but when ether3 is congested, then packets are going to be scheduled, we can configure the switch to hold lowest priority packets until all higher priority packets are sent out, this is a very common scenario for VoIP type setups, where some traffic needs to be prioritized.

To achieve such a behaviour, switch together ether1, ether2 and ether3 ports:

/interface bridge
add name=bridge1
/interface bridge port
add bridge=bridge1 interface=ether1 hw=yes
add bridge=bridge1 interface=ether2 hw=yes
add bridge=bridge1 interface=ether3 hw=yes

Enable Strict Policy for each internal queue on each port:

/interface ethernet switch port
set ether1,ether2,ether3 per-queue-scheduling="strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0,strict-priority:0"

Map each PCP value to an internal priority value, for convenience reasons simply map PCP to an internal priority 1-to-1:

/interface ethernet switch port
set ether1,ether2,ether3 pcp-based-qos-priority-mapping=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7

Since the switch will empty the largest queue first and you need the highest priority to be served first, then you can assign this internal priority to a queue 1-to-1:

/interface ethernet switch port
set ether1,ether2,ether3 priority-to-queue=0:0,1:1,2:2,3:3,4:4,5:5,6:6,7:7

Finally, set each switch port to schedule packets based on the PCP value:

/interface ethernet switch port
set ether1,ether2,ether3 qos-scheme-precedence=pcp-based

Bandwidth Limiting

Both Ingress Port policer and Shaper provide bandwidth limiting features for CRS switches.

  • Ingress Port Policer sets RX limit on port:
/interface ethernet switch ingress-port-policer
add port=ether5 meter-unit=bit rate=10M
  • Shaper sets TX limit on port:
/interface ethernet switch shaper
add port=ether5 meter-unit=bit rate=10M

Traffic Storm Control

The same Ingress Port policer also can be used for the traffic storm control to prevent disruptions on Layer 2 ports caused by broadcast, multicast or unicast traffic storms.

  • Broadcast storm control example on ether5 port with 500 packet limit per second:
/interface ethernet switch ingress-port-policer
add port=ether5 rate=500 meter-unit=packet packet-types=broadcast 
  • Example with multiple packet types which includes ARP and ND protocols and unregistered multicast traffic. Unregistered multicast is traffic which is not defined in Multicast Forwarding database.
/interface ethernet switch ingress-port-policer
add port=ether5 rate=5k meter-unit=packet packet-types=broadcast,arp-or-nd,unregistered-multicast

See also

[ Top | Back to Content ]