Manual:CRS1xx/2xx series switches: Difference between revisions
added CRS MAC VLAN table |
added CRS VLAN table |
||
Line 797: | Line 797: | ||
<td><var><b>src-mac-address</b></var> (<em>MAC address</em>)</td> | <td><var><b>src-mac-address</b></var> (<em>MAC address</em>)</td> | ||
<td>Matching source MAC address for MAC based VLAN rule.</td> | <td>Matching source MAC address for MAC based VLAN rule.</td> | ||
</tr> | |||
</table> | |||
<p></p> | |||
===VLAN Table=== | |||
<p id="shbox"><b>Sub-menu:</b> <code>/interface ethernet switch | |||
vlan</code></p><br /> | |||
The VLAN table supports 4k VLAN entries for storing VLAN member information as | |||
well as | |||
other VLAN information such as QoS, isolation, forced VLAN, learning, and | |||
mirroring. | |||
<table class="styled_table"> | |||
<tr> | |||
<th width="50%">Property</th> | |||
<th >Description</th> | |||
</tr> | |||
<tr> | |||
<td><var><b>disabled</b></var> (<em>yes | no</em>; Default: <b>no</b>)</td> | |||
<td>Indicate whether the VLAN entry is disabled. Only enabled entry is | |||
applied to lookup process and forwarding decision.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>flood</b></var> (<em>yes | no</em>; Default: <b>no</b>)</td> | |||
<td>Enables or disables forced VLAN flooding per VLAN. If the feature is | |||
enabled, the result of destination MAC lookup in the UFDB or MFDB is ignored, | |||
and the packet is forced to flood in the VLAN.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>ingress-mirror</b></var> (<em>yes | no</em>; Default: | |||
<b>no</b>)</td> | |||
<td>Enable the ingress mirror per VLAN to support the VLAN-based mirror | |||
function.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>isolation-profile</b></var> (<em>community1 | community2 | | |||
isolated | promiscuous</em>; Default: <b>promiscuous</b>)</td> | |||
<td>VLAN level isolation profile. </td> | |||
</tr> | |||
<tr> | |||
<td><var><b>ports</b></var> (<em>ports</em>)</td> | |||
<td>Member ports of the VLAN.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>qos-group</b></var> (<em>none</em>; Default: <b>none</b>)</td> | |||
<td>Defined QoS group from "QoS group" menu.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>sa-learning</b></var> (<em>yes | no</em>; Default: | |||
<b>no</b>)</td> | |||
<td>Enables or disables source MAC learning for VLAN.</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>svl</b></var> (<em>yes | no</em>; Default: <b>no</b>)</td> | |||
<td> | |||
FDB lookup mode for lookup in UFDB and MFDB. | |||
* Shared VLAN Learning (svl) - learning/lookup is based on MAC addresses - | |||
not on VLAN IDs. | |||
* Independent VLAN Learning (ivl) - learning/lookup is based on both MAC | |||
addresses and VLAN IDs. | |||
</td> | |||
</tr> | |||
<tr> | |||
<td><var><b>vlan-id</b></var> (<em>0..4095</em>)</td> | |||
<td>VLAN id of the VLAN member entry.</td> | |||
</tr> | </tr> | ||
</table> | </table> | ||
<p></p> | <p></p> |
Revision as of 09:42, 29 January 2014
Applies to RouterOS: v6.8 +
Summary
The Cloud Router Switch series are highly integrated switches with high performance MIPS CPU and feature-rich packet processor. The CRS switches can be designed into various Ethernet applications including unmanaged switch, Layer 2 managed switch, carrier switch and wireless/wired unified packet processing.
Abbreviations and Explanations
CVID - Customer VLAN id: inner VLAN tag id of the IEEE 802.1ad frame
SVID - Service VLAN id: outer VLAN tag id of the IEEE 802.1ad frame
IVL - Independent VLAN learning - learning/lookup is based on both MAC addresses and VLAN IDs.
SVL - Shared VLAN learning - learning/lookup is based on MAC addresses - not on VLAN IDs.
TPID - Tag Protocol Identifier
PCP - Priority Code Point: a 3-bit field which refers to the IEEE 802.1p priority
DEI - Drop Eligible Indicator
DSCP - Differentiated services Code Point
Drop precedence - internal CRS switch QoS attribute used for packet enqueuing or dropping.
Generic Configuration
Sub-menu: /interface ethernet switch
CRS switch chip is configurable from the /interface ethernet switch
console menu.
Property | Description |
---|---|
bridge-type (customer-vlan-bridge | service-vlan-bridge; Default: service-vlan-bridge) | Bridge type defines which VLAN tag is used as Lookup-VID. Lookup-VID serves as the VLAN key for all VLAN-based lookup. |
bypass-l2-security-check-filter-for (protocols; Default: none) | Protocols which are excluded from Policy rule security check. (arp, dhcpv4, dhcpv6, eapol, igmp, mld, nd, pppoe-discovery, ripv1) |
bypass-vlan-ingress-filter-for (protocols; Default: none) | Protocols which are excluded from Ingress VLAN filtering. These
protocols are not dropped if they have invalid VLAN. (arp, dhcpv4, dhcpv6, eapol, igmp, mld, nd, pppoe-discovery, ripv1) |
drop-if-invalid-or-src-port-
-not-member-of-vlan-on-ports (ports; Default: none) |
Ports which drop invalid and other port VLAN id frames. |
drop-if-no-vlan-assignment-on-ports (ports; Default: none) | Ports which drop frames if no VLAN assignment is applied. |
egress-mirror-ratio (1/32768..1/1; Default: 1/1) | Proportion of egress mirrored packets compared to all packets. |
egress-mirror0-enable (yes | no; Default: yes) | Enables or disables egress mirroring on Mirror0 port. |
egress-mirror0-format (analyzer-configured | modified | original; Default: modified) |
|
egress-mirror0-port (port; Default: switch1-cpu) | The first egress mirroring analyzer port. |
egress-mirror1-enable (yes | no; Default: yes) | Enables or disables egress mirroring on Mirror1 port. |
egress-mirror1-format (analyzer-configured | modified | original; Default: modified) |
|
egress-mirror1-port (port; Default: switch1-cpu) | The second egress mirroring analyzer port. |
egress-sampling-ratio (1/32768..1/1; Default: 1/1) | |
fdb-uses (mirror0 | mirror1; Default: mirror0) | Analyzer port used for FDB-based mirroring. |
forward-invalid-vlan (yes | no; Default: yes) | Whether to allow forwarding VLANs which are not members of VLAN table. |
ingress-mirror-ratio (1/32768..1/1; Default: 1/1) | Proportion of ingress mirrored packets compared to all packets. |
ingress-mirror0-enable (yes | no; Default: yes) | Enables or disables ingress mirroring on Mirror0 port. |
ingress-mirror0-format (analyzer-configured | modified | original; Default: modified) |
|
ingress-mirror0-port (port; Default: switch1-cpu) | The first ingress mirroring analyzer port. |
ingress-mirror1-enable (yes | no; Default: yes) | Enables or disables ingress mirroring on Mirror1 port. |
ingress-mirror1-format (analyzer-configured | modified | original; Default: modified) |
|
ingress-mirror1-port (port; Default: switch1-cpu) | The second ingress mirroring analyzer port. |
invalid-vlan-lookup-mode (ivl | svl; Default: ivl) | Lookup and learning mode for packets with invalid VLAN. |
ipv4-multicast-lookup-mode
(dst-ip-and-vid-for-ipv4 | dst-mac-and-vid-always; Default: dst-mac-and-vid-always) |
Lookup mode for IPv4 multicast bridging.
|
mac-level-isolation (yes | no; Default: no) | Enables or disables MAC level isolation. |
mirror-egress-if-ingress-mirrored (yes | no; Default: no) | When packet is applied to both ingress and egress mirroring, if this
setting is disabled, only ingress mirroring is performed on the packet; if this setting is enabled both mirroring types are applied. |
mirror-tx-on-mirror-port (yes | no; Default: no) | |
mirrored-packet-drop-precedence (drop | green | red | yellow; Default: green) | Remarked drop precedence in mirrored packets. This QoS attribute is used for mirrored packet enqueuing or dropping. |
mirrored-packet-qos-priority (0..7; Default: 0) | Remarked priority in mirrored packets. |
name (string value; Default: switch1) | Name of the switch. |
override-existing-when-ufdb-full (yes | no; Default: no) | Enable or disable to override existing entry which has the lowest aging value when UFDB is full. |
unicast-fdb-timeout (time interval; Default: 5m) | Timeout for Unicast FDB entries. |
use-cvid-in-one2one-vlan-lookup (yes | no; Default: yes) | Whether to use customer VLAN id for 1:1 VLAN switching lookup. |
use-svid-in-one2one-vlan-lookup (yes | no; Default: no) | Whether to use service VLAN id for 1:1 VLAN switching lookup. |
vlan-level-isolation (yes | no; Default: no) | Enables or disables VLAN level isolation. |
vlan-uses (mirror0 | mirror1; Default: mirror0) | Analyzer port used for VLAN-based mirroring. |
Port Configuration
Sub-menu: /interface ethernet switch
port
Property | Description |
---|---|
action-on-restricted-unknown-sa (copy-to-cpu | drop | forward | redirect-to-cpu; Default: forward) | Forwarding action for packets with restricted unknown source MAC address. |
action-on-static-station-move (copy-to-cpu | drop | forward | redirect-to-cpu; Default: forward) | Forwarding action for packets with normal static station move. |
allow-multicast-loopback (yes | no; Default: no) | Multicast loopback on port. When enabled, it permits sending back when
source port and destination port are the same for registered multicast or broadcast packets. |
allow-unicast-loopback (yes | no; Default: no) | Unicast loopback on port. When enabled, it permits sending back when
source port and destination port are the same one for known unicast packets. |
default-customer-pcp (0..7; Default: 0) | Default customer priority of the port. |
default-service-pcp (0..7; Default: 0) | Default service priority of the port. |
drop-counter-config (; Default: none) | |
drop-when-ufdb-entry-sa-drop (yes | no; Default: no) | Enable or disable to drop packets when UFDB entry has action "src-drop". |
dynamic-mac-move-is-restricted-unknown-sa (yes | no; Default: no) | |
egress-customer-tpid (0..10000; Default: 0x8100) | |
egress-mirror-to (mirror0 | mirror1; Default: mirror0) | Analyzer port for port-based egress mirroring. |
egress-mirroring (yes | no; Default: no) | Enable or disable egress mirroring on the port. |
egress-pcp-propagation (yes | no; Default: no) | Enables or disables egress PCP propagation.
|
egress-sampling (yes | no; Default: no) | |
egress-service-tpid (0..10000; Default: 0x88A8) | |
egress-vlan-lookup (according-to-bridge-type |
according-to-egress-vlan-type; Default: according-to-egress-vlan-type) |
Egress VLAN table (VLAN Tagging) lookup:
|
egress-vlan-mode (tagged | unmodified | untagged; Default: unmodified) | Egress VLAN tagging action on the port. |
egress-vlan-type (edge-port | network-port; Default: edge-port) | Port type for Egress VLAN lookup. |
filter-priority-tagged-frame (yes | no; Default: no) | Whether to filter tagged frames with priority on the port. |
filter-tagged-frame (yes | no; Default: no) | Whether to filter tagged frames on the port. |
filter-untagged-frame (yes | no; Default: no) | Whether to filter untagged frames on the port. |
ingress-customer-tpid (0..10000; Default: 0x8100) | |
ingress-mirror-to (mirror0 | mirror1; Default: mirror0) | Analyzer port for port-based ingress mirroring. |
ingress-mirroring (yes | no; Default: no) | Enable or disable ingress mirroring on the port. |
ingress-mirroring-according-to-vlan (yes | no; Default: no) | |
ingress-sampling (yes | no; Default: no) | |
ingress-sampling-mode
(all-frames-excluding-filtered | all-frames-without-mac-error; Default: all-frames-without-mac-error) |
|
ingress-sampling-ratio (1/32768..1/1; Default: 1/1) | |
ingress-service-tpid (0..10000; Default: 0x88A8) | |
ingress-vlan-type (edge-port | network-port; Default: edge-port) | |
isolation-profile (0..31; Default: 30) |
|
learn (yes | no; Default: ) | Enable or disable MAC address learning on the port. |
learn-limit (1..1023; Default: ) | Number of allowed MAC address limit of the port. |
learn-restricted-unknown-sa (yes | no; Default: yes) | Enable to learn restricted unknown source MAC. Source MAC is classified
as Restricted Unknown if any one of the following conditions are met:
|
mac-based-customer-vlan-for (all-frames | none |
tagged-frame-only | untagged-and-priority-tagged-frame-only; Default: none) |
Frame type for which applies MAC-based customer VLAN translation. |
mac-based-service-vlan-for (all-frames | none |
tagged-frame-only | untagged-and-priority-tagged-frame-only; Default: none) |
Frame type for which applies MAC-based service VLAN translation. |
mac-based-vlan-translate (yes | no; Default: no) | Enable or disable MAC-based VLAN translation on the port. |
mac-vlan-type (edge-port | network-port; Default: edge-port) | Port type for MAC based VLAN translation. |
pcp-propagation-for-initial-pcp (yes | no; Default: no) | |
per-queue-scheduling (strict-priority | wrr-group0 | wrr-group1; Default: ) | |
priority-to-queue (; Default: 0-15:0,1:1,2:2,3:3) | |
qos-change-dei (yes | no; Default: no) | Whether to change DEI on the port. |
qos-change-dscp (yes | no; Default: no) | Whether to change DSCP on the port. |
qos-change-pcp (yes | no; Default: no) | Whether to change PCP on the port. |
qos-dscp-to-dscp-mapping (yes | no; Default: no) | Enable or disable DSCP mapping on the port. |
qos-pcp-dei-map-dei (; Default: 0-15:0) | |
qos-pcp-dei-map-drop-precedence (; Default: 0-15:green) | |
qos-pcp-dei-map-dscp (; Default: 0-15:0) | |
qos-pcp-dei-map-pcp (; Default: 0-15:0) | |
qos-pcp-dei-map-priority (yes | no; Default: 0-15:0) | |
qos-scheme-precedence (da-based | dscp-based |
pcp-based | protocol-based | sa-based | vlan-based; Default: pcp-based) |
|
secure-static-mac-move-is-restricted-unknown-sa (yes | no; Default: no) |
Ingress/Egress VLAN Translation
Sub-menu: /interface ethernet switch
ingress-vlan-translation
Sub-menu: /interface ethernet switch
egress-vlan-translation
Property | Description |
---|---|
customer-dei (0..1; Default: none) | Matching DEI of the customer tag. |
customer-pcp (0..7; Default: none) | Matching PCP of the customer tag. |
customer-vid (0..4095; Default: none) | Matching VLAN id of the customer tag. |
customer-vlan-lookup-for (all |
priority-tagged-or-tagged | tagged | untagged-or-tagged; Default: untagged-or-tagged) |
Type of frames with customer tag for which VLAN translation rule is valid. |
disabled (yes | no; Default: no) | Enables or disables VLAN translation entry. |
new-customer-vid (0..4095; Default: none) | The new customer VLAN id which replaces matching customer VLAN id. |
new-service-vid (0..4095; Default: none) | The new service VLAN id which replaces matching service VLAN id. |
pcp-propagation (yes | no; Default: no) | Enables or disables PCP propagation.
|
port (port) | Matching switch port for VLAN translation rule. |
protocol (protocols; Default: none) | Matching Ethernet protocol. |
sa-learning (yes | no; Default: no) | Enables or disables source MAC learning after VLAN translation. |
service-dei (0..1; Default: none) | Matching DEI of the service tag. |
service-pcp (0..7; Default: none) | Matching PCP of the service tag. |
service-vid (0..4095; Default: none) | Matching VLAN id of the service tag. |
service-vlan-lookup-for (all |
priority-tagged-or-tagged | tagged | untagged-or-tagged; Default: untagged-or-tagged) |
Type of frames with service tag for which VLAN translation rule is valid. |
swap-vids (yes | no; Default: no) | Allows swapping original service VLAN id with original customer VLAN id. |
Protocol Based VLAN
Sub-menu: /interface ethernet switch
protocol-based-vlan
Protocol Based VLAN table is used to assign VID and QoS attributes to related protocol packet per port.
Property | Description |
---|---|
disabled (yes | no; Default: no) | Enables or disables Protocol Based VLAN entry. |
frame-type (ethernet | llc | rfc-1042; Default: ethernet) | Encapsulation type of the matching frames. |
new-customer-vid (0..4095; Default: 0) | The new customer VLAN id which replaces original customer VLAN id for specified protocol. |
new-service-vid (0..4095; Default: 0) | The new service VLAN id which replaces original service VLAN id for specified protocol. |
port (port) | Matching switch port for Protocol based VLAN rule. |
protocol (protocol; Default: 0) | Matching protocol for Protocol based VLAN rule. |
qos-group (none; Default: none) | Defined QoS group from "QoS group" menu. |
set-customer-vid-for (all | none | tagged | untagged-or-priority-tagged; Default: none) | Customer VLAN id assignment command for different packet type. |
set-qos-for (all | none | tagged | untagged-or-priority-tagged; Default: none) | Frame type for which QoS assignment command applies. |
set-service-vid-for (all | none | tagged | untagged-or-priority-tagged; Default: none) | Service VLAN id assignment command for different packet type. |
MAC Based VLAN
Sub-menu: /interface ethernet switch
mac-based-vlan
MAC Based VLAN table is used to assign VLAN based on source MAC.
Property | Description |
---|---|
disabled (yes | no; Default: no) | Enables or disables MAC Based VLAN entry. |
new-customer-vid (0..4095; Default: 0) | The new customer VLAN id which replaces original service VLAN id for matched packets. |
new-service-vid (0..4095; Default: 0) | The new service VLAN id which replaces original service VLAN id for matched packets. |
src-mac-address (MAC address) | Matching source MAC address for MAC based VLAN rule. |
VLAN Table
Sub-menu: /interface ethernet switch
vlan
The VLAN table supports 4k VLAN entries for storing VLAN member information as well as other VLAN information such as QoS, isolation, forced VLAN, learning, and mirroring.
Property | Description |
---|---|
disabled (yes | no; Default: no) | Indicate whether the VLAN entry is disabled. Only enabled entry is applied to lookup process and forwarding decision. |
flood (yes | no; Default: no) | Enables or disables forced VLAN flooding per VLAN. If the feature is
enabled, the result of destination MAC lookup in the UFDB or MFDB is ignored, and the packet is forced to flood in the VLAN. |
ingress-mirror (yes | no; Default: no) | Enable the ingress mirror per VLAN to support the VLAN-based mirror function. |
isolation-profile (community1 | community2 | isolated | promiscuous; Default: promiscuous) | VLAN level isolation profile. |
ports (ports) | Member ports of the VLAN. |
qos-group (none; Default: none) | Defined QoS group from "QoS group" menu. |
sa-learning (yes | no; Default: no) | Enables or disables source MAC learning for VLAN. |
svl (yes | no; Default: no) |
FDB lookup mode for lookup in UFDB and MFDB. * Shared VLAN Learning (svl) - learning/lookup is based on MAC addresses - not on VLAN IDs. * Independent VLAN Learning (ivl) - learning/lookup is based on both MAC addresses and VLAN IDs. |
vlan-id (0..4095) | VLAN id of the VLAN member entry. |