S+RJ10 general guidance: Difference between revisions
Line 10: | Line 10: | ||
==== S+RJ10 Positioning in devices ==== | ==== S+RJ10 Positioning in devices ==== | ||
Due | Due to high operating temperatures, we are recommending to use S+RJ10 transceivers with optical transceiver or unused SFP+ interface in between them. Take a look on the transceivers capable distance [https://wiki.mikrotik.com/wiki/MikroTik_SFP_module_compatibility_table#S.2BRJ10 comparison table]. | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- |
Revision as of 16:46, 30 January 2019
Summary
MikroTik S+RJ10 is a unique 6-speed RJ-45 SFP+ module that is based on a Marvell 88X3310P transceiver. It offers up to 10 Gbps speeds using twisted-pair copper cables. All of the current MikroTik devices that have an SFP+ cage support S+RJ10 module. This article serves as a guideline of the S+RJ10 usage in MikroTik devices with passive and active cooling.
General Guidance
Product specification
The average power consumption of the transceiver is 2.7 W (10GBASE-T, 30 m link). The operating temperature is 0 to +70 C, but the transceiver itself can heat up to 90 C.
S+RJ10 Positioning in devices
Due to high operating temperatures, we are recommending to use S+RJ10 transceivers with optical transceiver or unused SFP+ interface in between them. Take a look on the transceivers capable distance comparison table.
As mentioned, S+RJ10 heat up more than regular transceivers and keeping them side by side will heat them more than necessary, especially in devices with 4 linear SFP cages. We are recommending to place S+RJ10 in every second interface with keeping optical transceiver or empty port in between them. |
Even devices which come with separated SFP+ cages, for example CRS309-1G-8S+, we still do not recommend to use S+RJ10 transceivers beside each other. Use S+RJ10 in every second interface to avoid transceivers overheating which may cause unpredictable errors. |
Devices which come with 4 or 8 block SFP+ cages are not exceptions. We are recommending to use one S+RJ10 transceiver peer 4xSFP+ cage block and avoiding placing them side by side. Keep at least one vertical row empty(without S+RJ10) after plugged S+RJ10 transceiver. |
Using S+RJ10 side by side
It is not always possible to place transceivers in proper order. In cases where two or more S+RJ10 transceivers are plugged in beside, network administrator has to ensure additional cooling for such setup. It can be increased air flow or overall environment temperature refrigeration to keep transceiver temperature below recommended 90C.