| Even devices that come with separated SFP+ cages, for example CRS309-1G-8S+, it is still not recommended to | | Even when using devices that come with separated SFP+ cages, for example CRS309-1G-8S+, it is still not recommended to deploy the S+RJ10 transceivers beside each other. Use S+RJ10 in every second interface to avoid transceivers overheating which may cause unpredictable behavior. | ||
|[[file:20190129 125301.jpg|600px|center|thumb|alt=Alt text|Recommended S+RJ10 placement]] | |[[file:20190129 125301.jpg|600px|center|thumb|alt=Alt text|Recommended S+RJ10 placement]] | ||
[[file:20190129 125325.jpg|600px|center|thumb|alt=Alt text|It is not recommended to place transceivers side by side]] | [[file:20190129 125325.jpg|600px|center|thumb|alt=Alt text|It is not recommended to place transceivers side by side]] |
Revision as of 16:50, 30 January 2019
Summary
MikroTik S+RJ10 is a unique 6-speed RJ-45 SFP+ module that is based on a Marvell 88X3310P transceiver. It offers up to 10 Gbps speeds using twisted-pair copper cables. All of the current MikroTik devices that have an SFP+ cage support S+RJ10 module. This article serves as a guideline of the S+RJ10 usage in MikroTik devices with passive and active cooling.
General Guidance
Product specification
The average power consumption of the transceiver is 2.7 W (10GBASE-T, 30 m link). The operating temperature is 0 to +70 C, but the transceiver itself can heat up to 90 C.
S+RJ10 Positioning in devices
Due to high operating temperatures, it is recommended to use S+RJ10 transceivers with optical transceiver or an unused SFP+ interface in between them. Take a look on the transceivers capable distance comparison table.
As mentioned, S+RJ10 heat up more than regular transceivers and keeping them side by side can result in overheating, especially in devices with 4 linear SFP cages. It is recommended to place S+RJ10 in every second interface with keeping an optical transceiver or an empty port in between them. |
Even when using devices that come with separated SFP+ cages, for example CRS309-1G-8S+, it is still not recommended to deploy the S+RJ10 transceivers beside each other. Use S+RJ10 in every second interface to avoid transceivers overheating which may cause unpredictable behavior. |
Devices that come with 4 or 8 block SFP+ cages are not exceptions. It is recommended to use one S+RJ10 transceiver per 4xSFP+ cage block and avoided placing them side by side. Keep at least one vertical row empty(without S+RJ10) after plugged S+RJ10 transceiver. |
Using S+RJ10 side by side
It is not always possible to place transceivers in proper order. In cases where two or more S+RJ10 transceivers are plugged in beside, network administrator has to ensure additional cooling for such setup. It can be increased air flow or overall environment temperature refrigeration to keep transceiver temperature below recommended 90C.