Manual:Interface/Lora
Jump to navigation
Jump to search
Summary
Package: system
,lora
Every RouterBOARD with a miniPCI-e interface (with connected USB lines) could be turn in LoRaWAN gateway by installation of R11e-LoRa8 or R11e-LoRa9 card.
Warning: RouterOS doesn`t support 3rd party LoRaWAN gateway cards
Properties
Sub-menu: /lora
Property | Description |
---|---|
antenna-gain (integer [-128..127]; Default: 0) | Antenna gain in dBi. |
channel-plan (as-923 | au-915 | custom | eu-868 | in-865 | kr-920 | ru-864 | us-915; Default: eu-868) | Frequency plans for various regions. |
disabled (yes | no; Default: yes) | Whether LoRaWAN gateway is disabled. |
forward (crc-disabled | crc-error | crc-valid; Default: crc-valid,crc-error) | Defines what kind of packets should be forwarded to Network server:
|
lbt-enabled (yes | no; Default: no) | Whether gateway should use LBT (Listen Before Talk) protocol. |
listen-time (integer [0us..4294967295us]; Default: 5000us) | Time in microseconds to track RSSI before TX (used when lbt-enabled=yes). |
name (string; Default: ) | Name of LoRaWAN gateway. |
network (private | public; Default: public) | Whether sync word should be used (network=private) or shouldn`t (network=public). |
rssi-threshold (integer [-32,768 .. 32,767]; Default: -65dB) | RSSI value to determine whether forwarder may use specific channel to talk. If RSSI value is below rssi-threshold, channel could be used (used when lbt-enabled=yes). |
servers (list of string; Default: ) | Name or names of servers from /lora servers. |
src-address (IP; Default: ) | Specifies uplink packet source address if necessary (address should match an address configured on the RB). |